(b) Check operation of the air switching valve assembly.
(1) Check that air does not flow from port A to port B.
NOTICE:
Make sure that the applied pressure is 30 kPa (0.3 kgf/cm2, 4.4 psi) or less.
If the result is not as specified, replace the air switching valve assembly.
(2) Apply battery voltage across terminals 1 and 5.
NOTICE:
When applying voltage, do not touch terminals 2, 3, and 4.
(3) Check that air flows from port A to port B.
If the result is not as specified, replace the air switching valve assembly.
|